OMRON
Home >> Download >> OMRON >> Catalog Download >> OMRON K3HB-XAA-CPAC21 AC100-240 datasheet PDF catalog K3HB-XAA-CPAC21 AC100-240 PDF datasheet

OMRON K3HB-XAA-CPAC21 AC100-240 datasheet PDF catalog K3HB-XAA-CPAC21 AC100-240 PDF datasheet

Brand: OMRON
Product model: K3HB-XAA-CPAC21 AC100-240
Name: Voltage and current panel meter
Sort: PDF datasheet
File language: English
File size: 1.90MB
Rated input voltage: 3-phase 3-wire mode, 200, 220, 230, or 240 VAC.
Ideal for Monitoring 3-phase Power Supplies,
for Industrial Facilities and Equipment.
Greater resistance to inverter noise.
Monitor undervoltages, overvoltages, phase sequence, and phase loss,
in three-phase three-wire circuits with one unit K3HB-XAA-CPAC21 AC100-240 PDF datasheet.
One SPDT output relay, 5 A at 250 VAC (resistive load) K3HB-XAA-CPAC21 AC100-240
World-wide power specifications supported by one unit.
(Set with a rotary switch.).
Relay status can be monitored using LED indicator. Input type: PNP input type.
Event input terminal 5 points (HOLD, RESET) equipped with.
External power supply DC12V80mA.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input.
BCD+ transistor: -- NPN open collector (5 bit output +HH, H, PASS, L, LL) K3HB-XAA-CPAC21 AC100-240 PDF datasheet.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V.
Measurement of 2 points through the speed, time, or cycle of the digital time interval table.
Action determine the color, can switch the green / Red 2 kinds of color display.
Measurement of wide range of pulse interval time.
Measuring, calculating and displaying the pulse interval between 2 points K3HB-XAA-CPAC21 AC100-240 PDF datasheet.
Pulse interval measurement range, the mostModel: DSR (67S).
Protection of distributed power supply connection to power system,
The relay is smaller, and the protection unit is more enriched.
Waste heat generation system improve the comprehensive energy efficiency and the use of natural,
Energy of wind power generation, the spread of power is becoming more and more popular.
This relay is used to detect the internal fault of the user in the distributed power supply,
Power line accident of distributed power supply and relay protection system.
The relay can be meet in Japan (system connected instant points specified in the standard model),
Function, can be through more than 20 kinds of products to establish the best protection system.
Can also correspond to the generator and the electric side / internal tributaries.
Unit with 2 relaay elements K3HB-XAA-CPAC21 AC100-240 datasheet PDF catalog.
In each unit, the variable action time circuit is hidden, so that the coordination design is more convenient.
All aircraft equipped with a locking relay terminal.
DSR can correctly determiine the direction of the sudden drop in the voltage to 0 of the short-circuit accident K3HB-XAA-CPAC21 AC100-240 datasheet PDF catalog.
2 stage cross terminal stand with cover with convenient wiring.
Related products
OMRON
Voltage and current panel meter
K3HB-XAA-CPAC11 AC100-240
OMRON Voltage and current panel meter K3HB-XAA-CPAC11 AC100-240
Type of input: AC current input. Output type
OMRON
Load sensor, mV instrument
K3HB-VLC-CPBC21 AC100-240
OMRON Load sensor, mV instrument K3HB-VLC-CPBC21 AC100-240
Category: external supply 100mA DC10V. Input
OMRON
Rotating pulse meter
K3HB-RNB-CPAC21 AC100-240
OMRON Rotating pulse meter K3HB-RNB-CPAC21 AC100-240
Input type: NPN/ voltage pulse input type. E
OMRON
Time interval table
K3HB-PPB-CPAC21 AC100-240
OMRON Time interval table K3HB-PPB-CPAC21 AC100-240
Input type: PNP input type. Event input term