OMRON
Home >> Download >> OMRON >> Manual Download >> OMRON E5CN-HQ2HH03D-FLK Basic Type Manual E5CN-HQ2HH03D-FLK User's Manual

OMRON E5CN-HQ2HH03D-FLK Basic Type Manual E5CN-HQ2HH03D-FLK User's Manual

Brand: OMRON
Product model: E5CN-HQ2HH03D-FLK
Name: Temperature Controller
Sort: User's Manual (Basic Type)
File language: English
File size: 6.14MB
Size: 48 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function E5CN-HQ2HH03D-FLK User's Manual.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input E5CN-HQ2HH03D-FLK
Communication: RS-422.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms E5CN-HQ2HH03D-FLK User's Manual.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-Thermo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output E5CN-HQ2HH03D-FLK User's Manual.
Through the infrared port can be carried out from the front of the communication.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. Size: 48 x 48mm.
Body: terminal type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
SSR fault detection function for heater with broken line: detection function for single phase heater.
Event entry point: 2.
Transfer output: -.
Communication: -.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance, using a new type of liquid crystal, visual angle, contrast to enhance.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
All models (thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensorss E5CN-HQ2HH03D-FLK Basic Type Manual.
Add PV/SV state display function, to see the state of the thermostat.
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
By supporting software (CX-ThermoVer.4.0) to carry out a simple function (AND/OR logic and delay),
Be able to eexecute flexible contact output
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault
Related products
OMRON
High performance temperature controller
E5CN-HQ2-W
OMRON High performance temperature controller E5CN-HQ2-W
Size: 48 x 48mm. Body: terminal type. Categor
OMRON
High performance temperature controller
E5CN-HQ2HBD
OMRON High performance temperature controller E5CN-HQ2HBD
Size: 48 x 48mm. Body: terminal type. Type: c
OMRON
Programmed temperature controller
E5CN-HTQ2H03D-FLK
OMRON Programmed temperature controller E5CN-HTQ2H03D-FLK
Size: 48 48mm, terminal type. Type: control
OMRON
High performance temperature controller
E5CN-HQ2H03-FLK
OMRON High performance temperature controller E5CN-HQ2H03-FLK
Size: 48 x 48mm. Body: terminal type. Categor